An RV with multiple Furrion Chill air-conditioning zones uses an electronic ceiling controller for each rooftop unit and a shared multi-zone wall thermostat. Furrion's wiring diagram shows the separate rooftop supplies, the low-voltage communication cables and the DIP-switch assignments that distinguish the zones.
Original Furrion wiring and installation illustrations
The original manufacturer's wiring and mounting figures are reproduced as links to Furrion's source PDFs. Open the document to enlarge terminals, switches and the roof layout.
Furrion multi-zone controller wiring connections
Open the PDF to enlarge the labelled components and connections.
Zone selection DIP switches and thermostat communication
Open the PDF to enlarge the labelled components and connections.
Open Zone selection DIP switches and thermostat communication (PDF)
Two-rooftop multi-zone RV wiring illustration
Open the PDF to enlarge the labelled components and connections.
Components, connections and model numbers
Each row identifies a part or connection in the selected Furrion configuration. Links are provided for matching NewRVParts products; different control generations are kept separate.
| Component | Model / description | NewRVParts link |
|---|---|---|
| Multi-zone controller | FACC12ESHA2-BL-AM — enhanced electronic ceiling control | View FACC12ESHA2-BL-AM |
| Wall thermostat | FACW12ESZA2-BL-AM — R32 multi-zone wall control | View FACW12ESZA2-BL-AM |
| Electronic ADB | FACT12CA2-PS-AM — ceiling air distribution assembly | View FACT12CA2-PS-AM |
| Zone 1 | DIP 1 OFF / DIP 2 OFF | |
| Zone 2 | DIP 1 OFF / DIP 2 ON | |
| Zone 3 | DIP 1 ON / DIP 2 OFF | |
| Zone 4 | DIP 1 ON / DIP 2 ON | |
| Furnace setting | DIP 4 controls furnace enablement for the selected zone | |
| Controller power | 12VDC supplied to each active electronic ceiling control | |
| Rooftop power | Independent 115VAC supply for each cooling unit | |
| Inter-zone link | Four-conductor communication cable between controllers and thermostat | |
| Sensor and harness | Freeze sensor plus wall-controller communication wiring | |
| Rooftop example | FACR15HESA2-PS-AM — white R32 rooftop unit | View FACR15HESA2-PS-AM |
Related products with NewRVParts photographs
Compare the parts and complete equipment shown below, then open a listing to check the full manufacturer part number, included pieces and original model before ordering.




Confirm the correct system or model
The FACC12ESHA2-BL-AM enhanced multi-zone controller matches the FACW12ESZA2-BL-AM multi-zone thermostat for the documented R32 system. Each zone still requires an electronic air distribution box and appropriate rooftop unit. A single-zone controller is not automatically equivalent to the enhanced multi-zone control.
Furrion uses DIP 1 and DIP 2 to choose zone 1, 2, 3 or 4; DIP 4 addresses the furnace, and the system requires separate 12V and 115V supplies as shown. Only the appropriate furnace-control zone should be enabled. Keep the analog integration wires separate from the normal digital thermostat communication path. The stocked C-FACR15SA-A02 heat strip is described by Furrion for a manual ADB, so it is not recommended here as a general electronic upgrade.