A manual-control Furrion Chill system uses two knobs on the ceiling air-distribution box to control fan operation and temperature. The manufacturer illustrations show the connection between the rooftop unit, the ADB and the manual controller—without requiring an electronic wall thermostat.

Original Furrion wiring and installation illustrations

The original manufacturer's wiring and mounting figures are reproduced as links to Furrion's source PDFs. Open the document to enlarge terminals, switches and the roof layout.

Furrion manual ADB and controller parts selection

Manufacturer diagram

Open the PDF to enlarge the labelled components and connections.

Open Furrion manual ADB and controller parts selection (PDF)

Manual control ADB system-wire connection

Manufacturer diagram

Open the PDF to enlarge the labelled components and connections.

Open Manual control ADB system-wire connection (PDF)

Components, connections and model numbers

Each row identifies a part or connection in the selected Furrion configuration. Links are provided for matching NewRVParts products; different control generations are kept separate.

Component Model / description NewRVParts link
Air-distribution box FACT11CA2-PS-AM — manual-knob ceiling assembly View FACT11CA2-PS-AM
Manual controller FACC10MESA2-BL-AM — separate manual single-zone control box View FACC10MESA2-BL-AM
Rooftop interface Factory harness from compatible R32 rooftop air conditioner
115V supply Rooftop/control electrical power connection
Temperature knob Manual room-temperature setting at ADB
Mode knob Fan/cooling/off selection at ADB
Cooling airflow Ceiling outlet and filter assembly
Duct-divider placement Avoid mixing return air with conditioned discharge air
Wall thermostat Not part of the manual-control pathway
Heat strip C-FACR15SA-A02 — optional 1,500W manual-ADB kit View C-FACR15SA-A02
Rooftop example FACR13HESA2-PS-AM — separately purchased R32 rooftop A/C View FACR13HESA2-PS-AM

Related products with NewRVParts photographs

Compare the parts and complete equipment shown below, then open a listing to check the full manufacturer part number, included pieces and original model before ordering.

Confirm the correct system or model

Use FACT11CA2-PS-AM for a compatible R32 manual air-distribution installation, together with the matching manual control box FACC10MESA2-BL-AM. The manual ADB is different from the visually similar FACT12CA2 electronic ADB. A single-zone wall thermostat is not the control method for the manual-knob setup.

Furrion identifies C-FACR15SA-A02 as a 1,500W supplementary heat-strip installation kit for a manual ADB configuration. The heat strip does not replace the RV furnace and does not make a cooling-only rooftop unit a heat pump. Check the roof opening, electrical circuit and kit instructions before adding supplemental heat.

R32 refrigerant is flammable. Refrigerant-system service and electrical installation must be handled by qualified personnel. Disconnect the 115V and any 12V supplies, follow equipment nameplate ratings and do not mix components designed for R410A with R32-only systems.

Boletín de piezas para vehículos recreativos

¡Suscríbase para futuras promociones!

Sobre NewRVParts

NewRVParts es un proveedor exclusivamente en línea de piezas y accesorios nuevos para vehículos recreativos (RV), equipos para autocaravanas, piezas para remolques y enganches, accesorios para camiones y productos marinos. Atendemos a clientes en todo Canadá y Estados Unidos, con productos de fabricantes de confianza enviados a través de una amplia red de distribución norteamericana. Compre en línea repuestos, equipos y accesorios que se entregan directamente en su puerta.