A manual-control Furrion Chill system uses two knobs on the ceiling air-distribution box to control fan operation and temperature. The manufacturer illustrations show the connection between the rooftop unit, the ADB and the manual controller—without requiring an electronic wall thermostat.
Original Furrion wiring and installation illustrations
The original manufacturer's wiring and mounting figures are reproduced as links to Furrion's source PDFs. Open the document to enlarge terminals, switches and the roof layout.
Furrion manual ADB and controller parts selection
Open the PDF to enlarge the labelled components and connections.
Open Furrion manual ADB and controller parts selection (PDF)
Manual control ADB system-wire connection
Open the PDF to enlarge the labelled components and connections.
Components, connections and model numbers
Each row identifies a part or connection in the selected Furrion configuration. Links are provided for matching NewRVParts products; different control generations are kept separate.
| Component | Model / description | NewRVParts link |
|---|---|---|
| Air-distribution box | FACT11CA2-PS-AM — manual-knob ceiling assembly | View FACT11CA2-PS-AM |
| Manual controller | FACC10MESA2-BL-AM — separate manual single-zone control box | View FACC10MESA2-BL-AM |
| Rooftop interface | Factory harness from compatible R32 rooftop air conditioner | |
| 115V supply | Rooftop/control electrical power connection | |
| Temperature knob | Manual room-temperature setting at ADB | |
| Mode knob | Fan/cooling/off selection at ADB | |
| Cooling airflow | Ceiling outlet and filter assembly | |
| Duct-divider placement | Avoid mixing return air with conditioned discharge air | |
| Wall thermostat | Not part of the manual-control pathway | |
| Heat strip | C-FACR15SA-A02 — optional 1,500W manual-ADB kit | View C-FACR15SA-A02 |
| Rooftop example | FACR13HESA2-PS-AM — separately purchased R32 rooftop A/C | View FACR13HESA2-PS-AM |
Related products with NewRVParts photographs
Compare the parts and complete equipment shown below, then open a listing to check the full manufacturer part number, included pieces and original model before ordering.




Confirm the correct system or model
Use FACT11CA2-PS-AM for a compatible R32 manual air-distribution installation, together with the matching manual control box FACC10MESA2-BL-AM. The manual ADB is different from the visually similar FACT12CA2 electronic ADB. A single-zone wall thermostat is not the control method for the manual-knob setup.
Furrion identifies C-FACR15SA-A02 as a 1,500W supplementary heat-strip installation kit for a manual ADB configuration. The heat strip does not replace the RV furnace and does not make a cooling-only rooftop unit a heat pump. Check the roof opening, electrical circuit and kit instructions before adding supplemental heat.