Adding a fused 12V or 24V accessory distribution point to an RV? The Egis RT range offers six- and twelve-output fuse blocks with clear covers and blown-fuse LED indicators. The key choice between 8025, 8026, 8028 and 8029 is whether you need six or twelve fused circuits and whether a separate ground-return section should come with the block.

Which RT block includes a ground-return section?

The fuse block carries the positive branch supply through individual blade fuses. The ground-return section is a separate set of negative connections; it is not another bank of fused positive outputs.

80256 fused outputs · ground section
Fused DC positive outputs (conceptual grouping)
123456
Included 12-position ground-return terminal block
802612 fused outputs · ground section
Fused DC positive outputs (conceptual grouping)
123456789101112
Included 12-position ground-return terminal block
80286 fused outputs · no ground section
Fused DC positive outputs (conceptual grouping)
123456
Negative/ground return is not included
802912 fused outputs · no ground section
Fused DC positive outputs (conceptual grouping)
123456789101112
Negative/ground return is not included
Original comparison illustration showing circuit counts and the presence or absence of a ground-return section. Numbers identify positions only, not their physical order, wiring or fuse sizes. For the factory's actual mounting drawings, refer to the exact model documentation.

Egis 8025 vs 8026 vs 8028 vs 8029

Egis part Fused outputs Ground return Block design
8025 6 Included 12-position section RT ATO/ATC with clear cover and blown-fuse LEDs
8026 12 Included 12-position section RT ATO/ATC with clear cover and blown-fuse LEDs
8028 6 Not included RT ATO/ATC with clear cover and blown-fuse LEDs
8029 12 Not included RT ATO/ATC with clear cover and blown-fuse LEDs

These RT blocks are designed for nominal 12V or 24V DC systems, with a manufacturer-stated operating range of 0–36V DC. Egis specifies 100A maximum for the complete block and 30A maximum per circuit. They accept ATO/ATC/ATF blade-fuse types; although the factory describes a range of available fuse sizes up to 40A, the block's 30A per-circuit rating and the connected wire and equipment ratings must still be respected.

The manufacturer lists two spare-fuse holding locations per six-output module. These are storage positions rather than additional energized circuits. RT blocks use ring-terminal output connections and stainless self-locking hardware; the covers help protect the connections and provide space for identification labels.

Choose by function, not appearance: 8025 and 8026 include a 12-position ground-return module, which Egis says can be detached for different cable routing. The 8028 and 8029 omit that module. If your installation already has a suitable negative bus, a model without the extra return block may be preferable.

Matching Egis RT fuse blocks and product photographs

Each card leads to the exact-number product listing in NewRVParts. Review the listing for ordering and stock details; these products ship from supplier warehouses and are not available for showroom pickup.

Egis 8025 6-circuit RT fuse block product photograph with ground-return section
Egis 8025 6-Circuit RT Fuse Block with GroundSix fused circuits with an included 12-position ground-return section.See product and availability
Egis 8026 12-circuit RT fuse block product photograph with ground-return section
Egis 8026 12-Circuit RT Fuse Block with GroundTwelve fuse outputs and a detachable ground-return section.See product and availability
Egis 8028 6-circuit RT fuse block product photograph
Egis 8028 6-Circuit RT Fuse BlockSix fused outputs without an included ground-return block.See product and availability
Egis 8029 12-circuit RT fuse block product photograph
Egis 8029 12-Circuit RT Fuse BlockTwelve fused outputs; use a separate suitable negative-return arrangement.See product and availability

Factory specifications and installation details

Egis documents the configurations and ratings in its RT ATO/ATC fuse-block range. See the manufacturer's 8025-series example and 8028-series example for details about removable ground modules and blown-fuse indicators.

Electrical installation: A fused block does not replace the need for properly sized source protection. Match fuse, cable, circuit load, mounting location and connection hardware to the manufacturer's instructions. Disconnect all battery and charging sources before electrical service.

Boletín de piezas para vehículos recreativos

¡Suscríbase para futuras promociones!

Sobre NewRVParts

NewRVParts es un proveedor exclusivamente en línea de piezas y accesorios nuevos para vehículos recreativos (RV), equipos para autocaravanas, piezas para remolques y enganches, accesorios para camiones y productos marinos. Atendemos a clientes en todo Canadá y Estados Unidos, con productos de fabricantes de confianza enviados a través de una amplia red de distribución norteamericana. Compre en línea repuestos, equipos y accesorios que se entregan directamente en su puerta.

Comprar piezas de RV