The Xantrex 709-3024-01 and 710-3024-01 are both 30A solar charge controllers, but they are different charging systems. The 709 uses PWM charging for one battery bank and has a 50V solar-array open-circuit limit. The 710 uses MPPT tracking, supports a higher-voltage solar array and provides separate outputs for a primary house battery and starter-battery maintenance.
Compare the matching products
Choose a product photograph to open its individual NewRVParts listing. Manufacturers use separate model numbers for different current ratings, charging methods and accessories.
709-3024-01 — Xantrex Solar 30A PWM Charge ControllerSingle-bank 30A PWM controller; max PV open-circuit voltage 50V
710-3024-01 — Xantrex MPPT 30A Dual-Bank Solar Controller30A primary-house / 1A starter-bank output; 100V maximum PV open-circuit
710-0010 — Xantrex MPPT-30 Remote Control PanelRemote status panel for the Xantrex MPPT-30
708-0150 — Xantrex Solar & Battery Cable Starter KitPre-terminated cable starter package; confirm length and conductor sizing
784-9115S-01 — Xantrex Solar Max 115W Flexible Panel115W panel example; system sizing depends on panel electrical ratings
Identify the correct model
| Xantrex controller | Technology and battery outputs | Maximum solar PV open-circuit voltage | Battery / solar system |
|---|---|---|---|
| 709-3024-01 | 30A PWM; one battery bank | 50V DC | 12V or 24V nominal system, automatic detection |
| 710-3024-01 | 30A MPPT house battery; 1A secondary starter output | 100V DC | 12V or 24V system; house and secondary banks must match nominal voltage |
Identify the terminals and optional equipment
The model-specific information below helps identify a terminal, installation component or separately listed accessory. It does not replace the manufacturer's electrical installation instructions.
| Terminal, part or component | Function | Important distinction |
|---|---|---|
| PV positive and negative input | Accepts solar-array DC power | 709 PWM manual specifies parallel panels only; 710 MPPT may use suitable series/parallel arrays within the maker's limits |
| Primary battery positive and negative | Connect to the house battery bank | Always follow the manufacturer connection order and required fusing |
| Battery 2 connection on 710 MPPT | Maintenance output for an additional starter battery | The 710 output for the secondary bank is rated only 1A; the 709 lacks this separate port |
| Chassis/common negative ground | Provides required grounding in the installation | Both controllers use a common-negative architecture; follow the exact manual |
| 710-0010 remote panel | Optional display/monitoring panel for the MPPT-30 | This separately sold remote belongs to 710-3024-01, not the PWM 709 controller |
| 708-0150 solar/battery cable kit | Pre-terminated PV and battery wiring starter package | Confirm wire lengths, gauge, protection and suitability for the installed solar array |
| 784-9115S-01 flexible solar panel | 115W Xantrex Solar Max panel example | A panel must be selected by electrical rating, mounting and total PV array design |
| Optional battery temperature sensor 708-0080 | Lead-acid temperature compensation where specified | Use only with supported battery types and the compatible accessory port |
| MPPT house-bank power limits | 710 rated charge power 390W at 12V, 780W at 24V | PV input maximum 580W at 12V or 1170W at 24V; different from rated charge output |
| Battery chemistry selection | Uses the selected manufacturer charging profile | Verify each bank's approved chemistry and BMS requirements before charging |
Original manufacturer installation reference
Refer to the factory document for terminal locations, wiring precautions, part identification and the correct connection procedure.