Parallel solar connections, string fuses and DC isolation each perform a different job in an RV photovoltaic system. This illustrated reference helps distinguish the Go Power 67049 / 67050 connector pair, Renogy 0022121 inline fuse and AIMS DC solar disconnect switches. The parts below are actual items in our catalog.
Follow the solar array components
When multiple compatible PV modules are wired in parallel, correctly matched branch connectors bring their output together. Any required string overcurrent protection and DC-rated disconnection must be selected for that array. The controller then manages battery charging according to its own input limits.
Combines parallel panel currents. The SC-BC-1M2F and SC-BC-1F2M differ in connector gender and work on opposite polarity sides of an approved arrangement.
An inline 20A solar fuse is not universal. Its rating must match conductor protection, the PV module's maximum series fuse rating and array design.
A DC-rated switch permits array isolation when properly installed. Voltage, current, poles and circuit configuration must match the actual PV system.
Model-number reference
| Exact component | Identification | Role |
|---|---|---|
| Go Power SC-BC-1M2F / 67049 | 1 male / 2 female | A branch connector of one polarity orientation |
| Go Power SC-BC-1F2M / 67050 | 1 female / 2 male | The matching opposite-polarity branch |
| Battle Born BBCBL-47 | 4-to-1 connector pair | For combining parallel solar leads, where approved |
| Renogy 0022121 | 20A inline fuse assembly | String overcurrent protection when specified |
| AIMS DC1200V32A / 1005959 | PV-rated DC disconnect | Isolation equipment; must match actual array conditions |
| AIMS DC1600V32A2IO / 1004532 | Dual-input/output DC disconnect | Different model and connection arrangement |
Connector housings that appear to fit are not automatically approved mating pairs. Check connector manufacturer, rating and contact compatibility. The number and direction of branches must be determined from the solar panel and controller installation instructions, not from connector appearance.
Shop branch, fuse and disconnect components
Solar branching components



PV fuse and DC disconnect components



Original manufacturer product references
For a safe system design, consult the exact module datasheet, wire and connector ratings, controller manual, and the documentation for the protective devices. The manufacturer resources below provide further details about the referenced parts.
Go Power solar branch connector references · Renogy inline fuse product reference · AIMS Power disconnect product resources