The SHURflo Revolution 4008 fresh-water pump can be serviced with specific head, valve, check-valve and pressure-switch components. Use the numbered Pentair exploded diagram to identify the failed assembly, then match the complete model number on your pump: the 12V, 24V and 115V versions use different motors.
Identify your Revolution 4008 pump
These three complete-pump listings show the different electrical versions. Pentair lists 3 GPM flow and a 55 PSI nominal shutoff rating for the models below; confirm the electrical rating on your old pump's label.
SHURflo Revolution 4008 exploded parts diagram
The numbered 4008 illustration appears on page 15 of Pentair's RV pump catalog (printed page 13). Positions 1–4 identify the upper housing, valve assembly, drive assembly and motor. The separate check valve and pressure switch do not have individual callout numbers in this drawing.

Open the full-size manufacturer diagram (PDF, page 15) — zoom in to read the small callouts. If your browser does not display the PDF above, use this link.
Numbered replacement-parts list
Pentair's service table identifies the following items for 4008-101, 4008-131 and 4008-171 OEM/aftermarket versions. Parts with links have exact-number NewRVParts listings; unlinked motor and drive references are for identification.
| Callout | Part number | Assembly | Models |
|---|---|---|---|
| 1 | 94-800-00 | Upper housing and switch assembly · View replacement | 4008-101 / 131 / 171 |
| 2 | 94-800-01 | Valve assembly · View replacement | 4008-101 / 131 / 171 |
| 3 | 94-800-02 | Diaphragm drive assembly | 4008-101 / 131 / 171 |
| 4 | 94-11-302-00 | Motor — 12V DC only | 4008-101 |
| 4 | 94-11-303-00 | Motor — 24V DC only | 4008-131 |
| 4 | 94-11-306-00 | Motor — 115V AC only | 4008-171 |
| 1–3 | 94-800-04 | Complete pump head assembly, excluding motor · View replacement | 4008-101 / 131 / 171 |
| Not shown | 94-800-03 | One-way check valve · View replacement | 4008-101 / 131 / 171 |
| Not shown | 94-800-05 | Pressure switch service part · View replacement | 4008-101 / 131 / 171 |
Check compatibility before ordering
The 12V 4008-101 series uses motor 94-11-302-00, the 24V 4008-131 uses 94-11-303-00, and the 115V 4008-171 uses 94-11-306-00. Do not interchange motors between voltage versions. The 4028 family uses a different upper housing, drive, complete head and switch even though the 94-800-01 valve assembly and 94-800-03 check valve also appear in its Pentair service table.
Browse all SHURflo pump parts diagrams by model
Genuine photos of matching 4008 repair kits
These are separate replacement assemblies, not complete pumps. The 94-800-04 head contains the pump-head positions shown on the drawing, while the 94-800-00 is the upper housing only. The motor is not included with the complete pump-head kit.
94-800-00 — Upper Housing AssemblyDiagram position 1 · upper housing and switch
94-800-01 — Valve AssemblyDiagram position 2 · not a complete pump head
94-800-04 — Complete Pump Head KitPositions 1, 2 and 3 as a repair assembly; motor separate
94-800-03 — One-Way Check ValveSeparate check valve · not individually called out in the exploded view